Development and Validation of UV-Spectroscopic Method for the Detection of Rutin from Eucalyptus globulus by using QbD Approach

 

Pratibha M. Khot1*, Laxmi B. Bagewadi2, Shital B. Khot2

1Assistant Professor, Department of Pharmaceutical Chemistry,

KLE’s College of Pharmacy, Nipani, 591237 Karnataka, India.

2B. Pharm Student, Department of Pharmaceutical Chemistry,

KLE’s College of Pharmacy, Nipani, Karnataka, India.

*Corresponding Author E-mail: pratibhakhot1987@gmail.com

 

ABSTRACT:

Rutin, a plant derived flavonoid with varied pharmacological and medicinal qualities, was successfully detected using a cost‑effective UV spectrophotometric method developed through the Quality by Design approach. To ensure sustainability, rutin was extracted from the leaves and roots of Eucalyptus globulus employing ultrasound‑assisted extraction with eco‑friendly solvents, highlighting the integration of green chemistry principles. The UV method was systematically optimized via QbD to achieve robustness, reproducibility, and environmental compatibility. Method validation was conducted in compliance with ICH Q2(R1) guidelines, covering linearity, accuracy, precision, robustness, and ruggedness, thereby validating its stability for routine analysis of herbal extracts. The developed method exhibited high degree of linearity across the concentration range of 10–50µg/mL with a correlation coefficient of 0.997. Sensitivity parameters were established, with the limit of detection and limit of quantification determined as 0.82µg/mL and 2.48µg/mL, respectively. Precision studies revealed low relative standard deviation values, while robustness and ruggedness assessments confirmed the reliability of the method under varied analytical conditions. The validated procedure was successfully applied for the detection and estimation of rutin in Eucalyptus globulus leaf and root extracts, demonstrating its practical utility in herbal formulations. Overall, this study establishes a novel, simple, precise, and sustainable Quality by design‑based UV spectrophotometric method for rutin detection. The integration of green extraction with validated analytical performance underscores its effectiveness for routine quality control and research applications in phytopharmaceuticals.

 

KEYWORDS: Rutin, Flavonoid, Quality by Design (QbD), Ultrasound‑assisted extraction (UAE), UV spectrophotometry.

 

 


INTRODUCTION:

Rutin (3,3′,4′,5,7-pentahydroxyflavone-3-rhamnoglucoside) is a flavonoid glycoside of quercetin and rutinose, abundant in S. involucrate. It exhibits versatile bioactivities, including antioxidant, anticarcinogenic, cytoprotective, antiplatelet, antithrombotic, vaso-protective, cardioprotective, and neuroprotective effectsą.

 

 

Rutin exhibits low water solubility but more soluble in methanol, resulting in low bioavailability in animals and humans. It occurs naturally in foods such as buckwheat, onions, apples, berries, citrus fruits, tea, and asparagus. Rutin has antioxidant and anti-inflammatory properties and is used in treating hemorrhage and varicose veins. It is marketed in tablets, capsules, and topical gels, either alone or in association with other actives. Tablets are the most common dosage form, formulated with excipients chosen for compatibility, solubility, and stability˛. Analytical methods such as liquid chromatography and UV spectrophotometry are widely employed, and sensitive techniques are needed to characterize its pharmacokinetics in intact glycoside formł.

 

 

Fig.1: Rutin

 

Eucalyptus globulus belonging to family Myrtaceae is widely distributed and traditionally used for inflammation, wound healing, respiratory ailments, throat diseases, and diabetes through topical formulations and leaf teas⁴. Eucalyptus leaf oil contains volatile terpenoids (cineole, pinene, limonene, aromadendrene) and phenolics (chlorogenic, gallic, ferulic, ellagic acids, catechins, flavonoids). These compounds exhibit antioxidant, anti-inflammatory, antimicrobial, and neuroprotective properties, with potential applications in pharmaceuticals, cosmetics, and food industries⁵. Green phytochemical recovery from Eucalyptus leaves includes EAE, MAE, UAE, and DES6. Ultrasound-assisted extraction (UAE) utilizes high-frequency sound waves to induce cavitation in the extraction medium, enhancing the release of phenolic compounds by disrupting plant cell walls. Relative to established methods, the technique demonstrates improved extraction performance, operational efficiency, energy conservation, and environmental safety through the use of aqueous solvents. Despite challenges in process optimization and scalability, UAE is considered a promising green technology for the extraction of phenolic compounds, adhering with the growing demand for eco-friendly solutions in the food industry6,8. This study aims to optimize selected process variables to maximize the recovery of flavonoids compounds from E. globulus leaves using Heat Assisted Extraction (HAE) and (UAE). The A Quality by Design (QbD) approach involves key steps: defining the Analytical Target Product Profile (ATPP), identifying Critical Analytical Attributes (CAA) such as accuracy, precision, and robustness, and determining Critical Method Attributes (CMA) like pH, injection volume, and column temperature. Design of experiments (DoE) establishes the design space, while method validation and control ensure reliable quality outcomes7,9.

 

MATERIALS AND METHODS:

Materials and Instrumentation:

UV-1800 spectrophotometer was used to measure absorbance. Balance was used to weigh sample accurately. Extraction of Rutin from plant material was carried out by using Ultrasonicator.

 

Chemicals and reagents:

Rutin marker was obtained from Yukka enterprises Wadala Mumbai. Analytical grade methanol, ethanol and ultra- pure water were obtained from the chemicals store house of KLE college of pharmacy, Nipani.

 

Plant material:

The roots and leaves of Eucalyptus Globulus was collected from local area of Nipani and then was kept in a desiccator at room temperature until used.

 

Method Development:

Establishment of Analytical procedures is a streamlined approach to designing reliable procedures for the identification, quantification, and analysis of chemical substances. In UV–Visible spectrophotometry, this process involves selecting correct solvents, determining the optimal wavelength for measurement, and constructing a calibration curve to confirm accuracy and precision.

 

Determination of solvent and Wavelength:

For the UV‑spectrophotometric analysis of Rutin, methanol was selected as the primary solvent due to its good solubility. A methanol–deionized water mixture (50:50) was employed for subsequent dilutions, chosen based on preliminary solubility and spectral clarity studies that demonstrated optimal drug solubility and a stable baseline absorbance. To determine the analytical wavelength, a 20µg/mL solution of Rutin was scanned across the UV range of 200–800nm, revealing a maximum absorbance at 256nm. Method parameters such as solvent composition and scanning speed were further optimized using a DoE approach within a QbD framework, ensuring robustness and reliability of the developed method.

Preparation of Standard Rutin solution:

Standard solution was prepared by dissolving accurate 10mg of Rutin in 10ml of methanol to get a concentration of 1000ug/mL. Further dilution the solvent methanol and deionized water (50:50v/v) was used to obtain final concentration 100ug/mL.

 

Preparation of working standard solution:

From above standard solution, aliquots having concentration range of 10-50μg/ml were prepared by using solvent methanol and deionized water (50:50v/v). The absorbance of all aliquots was measured at 256nm, the λmax of Rutin.

 

Extraction of Rutin from Eucalyptus Globulus leaves and roots:

The medicinal plant Eucalyptus globulus (family: Myrtaceae) was selected for the present study based on literature evidence supporting its flavonoid content, particularly rutin. Fresh leaves and roots of Eucalyptus globulus were collected  from local area of Nipani and authenticated at the Department of Botany, G.I. Bagewadi Arts, Science and Commerce College, Nipani  and confirmed as Eucalyptus globulus belonging to the family Myrtaceae, The collected plant parts (leaves and roots) were washed with water to remove soil and impurities, shade-dried at room temperature until constant weight to preserve flavonoids, powdered separately using a milling apparatus, passed through mesh #60, and stored in well closed containers for further experimental work. The powdered leaves and roots were then subjected separately to green extraction using UAE under the following conditions: sample weight 5g, solvent system ethanol: water (60:40v/v), extraction temperature 50–60°C, time 90minutes, sonication power 250W, and frequency 40kHz. After extraction, the mixtures were filtered through Whatman filter paper, and the filtrates (leaf and root extracts) were collected separately for analysis.

 

Preliminary phytochemical identification:

Both leaf and root extracts were subjected to flavonoid identification tests such as Ferric chloride test, Lead Acetate test, Sulphuric Acid test, Shinoda test etc.

 

Preparation of sample solution for UV:

One milliliter of the ethanolic extract of Eucalyptus leaves and roots was transferred into a 10mL volumetric flask, and the volume was made up to 10mL with a 50:50 (v/v) mixture of methanol and distilled water. The absorbance of the resulting solution was measured at 256 nm.

 

Optimization of Methodology using QbD principles:

Analytical QbD provides a robust engineering for methods. Within the AQbD framework, the first step is to establish the Analytical Target Profile (ATP). The ATP outlines the analytical objectives, including accuracy, precision, and robustness requirements, thereby guiding the choice of methodology and structuring subsequent design and development activities9. Following this, the CMPs are identified and evaluated for their influence on the CQAs using risk assessment tools. The set of CMPs that consistently achieve the desired CQAs determines the Design Space (DS), which acts as a multidimensional guideline for robust and consistent method operation.

 

Analytical Target Profile:

The ATP was developed to guide the establishment of robust UV spectrophotometric method for the estimation of the Rutin from the herbal extract.

 

Critical quality attributes:

In this study, the absorbance at 256nm was designated as the primary CQA, since it directly represents the method’s capability to accurately estimate rutin. Additionally, parameters such as linearity and precision were considered as supporting CQAs to reinforce the overall reliability of the method.

 

Design space:

The design space was developed using a central composite design (CCD) in Design-Expert® software. The Method Operable Design Region (MODR) was determined by evaluating the combined influence of solvent composition and scanning speed on absorbance at 256nm. This optimal region provided consistent method performance and robustness, thereby ensuring reliable estimation of rutin within the defined parameter range.

 

Control Strategy:

The control strategy was derived from the MODR, emphasizing the maintenance of solvent composition, scanning speed, and wavelength within the optimized limits to ensure method robustness and compliance with the Analytical Target Profile ATP9,10.

 

Software assisted optimization of experimental methods:

DOE is a structured methodology used to plan, conduct, and analyse experiments efficiently by varying multiple factors simultaneously. It encompasses key stages such as screening, optimization, and robustness testing, with the objective of identifying critical variables, optimizing outcomes, and ensuring method reliability while minimizing the number of experiments. The overall process can be summarized in the following steps.

 

Identification of experimental goals:

The aim of this study was to develop a robust UV spectrophotometric method for rutin detection using the QbD approach. Based on the chemical structure and UV absorbance characteristics of rutin, a detection wavelength of 256nm was selected. Method development was carried out using a solvent system comprising methanol and deionized water in a 50:50 (v/v) ratio.

 

Determining experimental variables and levels:

In this study, solvent composition and scanning speed were chosen as independent variables based on preliminary trials and literature reports. These controllable factors were examined at three levels using a DOE approach to evaluate their influence on the absorbance of Rutin.

 

Determining analytical responses:

Responses are dependent variables that are influenced by factor levels and selected according to the study objectives. In this study, absorbance at 256nm was chosen as the primary analytical response, as it directly reflects the method’s ability to accurately quantify rutin. This response was employed to assess the impact of the selected factors and to optimize method performance using statistical tools11.

 

Establishing the experimental design and model:

In UV spectrometry, a CCD was employed to optimize the method by assessing the influence of solvent composition and scanning speed on rutin absorbance. The design incorporated center and axial points to investigate potential interactions and quadratic effects, thereby facilitating efficient response surface modeling and the identification of optimal operating conditions11.

 

Method validation:

The UV spectrophotometric method was validated in accordance with ICH Q2(R1) guidelines, employing various validation parameters such as specificity, selectivity, linearity, limits of detection (LOD), limits of quantification (LOQ), precision, robustness, and ruggedness, as outlined below.

 

Selectivity and specificity:

Selectivity of an analytical method refers to its capability to accurately quantify the analyte in the presence of potential interferences originating from the sample matrix. Selectivity was assessed by comparing the absorption spectra of blank solvent, standard rutin solution, and sample extract at 256nm to confirm the absence of interfering absorbance. The raw data generated during selectivity testing must be documented in the approved formats to ensure transparency, reproducibility, and compliance with regulatory standards12,13.

 

Linearity and Range:

Linearity means that the method’s results increase in proportion to the analyte concentration, or can be expressed as proportional after suitable mathematical adjustment12,13.

 

Linearity was evaluated over the concentration range of 10–50µg/mL. The calibration curve exhibited a correlation coefficient of 0.997, with the intercept found to be statistically insignificant (P≥0.05), indicating minimal bias. The residual plot (Figure 4D) confirmed homoscedasticity, demonstrating consistent variance across concentrations. Standard solutions were prepared in a methanol–deionized water system (50:50v/v), and their absorbance was measured at 256nm.

 

Limit of detection and limit of quantification:

The LOD and LOQ were determined based on instrument sensitivity using linearity experiments. The LOD represents the lowest detectable concentration, corresponding to a signal-to-noise ratio of 1:3, while the LOQ denotes the lowest reliably quantifiable concentration, corresponding to a signal-to-noise ratio of 1:10. The values for rutin were calculated using calibration standards and the formulas LOD= 3x σ/ S and LOQ = 10x σ/S ,Where σ is standard deviation of the regression line’s y- intercept and S is the slope of the celebration curve.

 

Precision:

Precision reflects the consistency of test results when a method is repeatedly applied to multiple samples. It is evaluated by analyzing a series of standards or samples from a homogeneous lot and calculating the relative standard deviation (%RSD) using the standard deviation (SD) and mean values. The raw data are recorded in the approved format, with acceptance criteria defined in the study plan.

 

Robustness and Ruggedness:

Robustness refers to an analytical method’s ability to remain unaffected by small, intentional variations in parameters, thereby demonstrating its reliability under normal operating conditions. Ruggedness, on the other hand, evaluates the reproducibility of the method across different conditions such as analyst, instrument, and laboratory. Key factors typically assessed include temperature, and detection settings, depending on the analytical technique employed.

 

RESULTS AND DISCUSSION:

Method development:

A solvent system comprising methanol and deionized water (50:50, v/v) was employed for method development, wherein rutin demonstrated maximum absorbance at 256nm under medium scanning speed. The optimization of the method was performed in accordance with QbD principles.

 

Method optimization through QbD framework:

The method was systematically optimized following Quality by Design (QbD) principles, with the key steps outlined below:

 

Analytical target profile:

The ATP defined the desired method performance based on scientific understanding. It was established through literature review and drug profile evaluation, aiming to develop a fast, reliable, and economical UV spectrophotometric method for rutin. Table 1 presents the ATP.

 

Critical Quality Attributes:

CQAs represent essential analyte characteristics that must remain within acceptable limits to ensure method quality. For this UV method, drug absorbance was identified as the primary CQA.

 

Critical Method Parameters:

CMPs—including detection wavelength, solvent composition, and scanning speed—were selected based on their influence on absorbance response, sensitivity, and method robustness. These parameters were identified through preliminary screening studies.

 

Risk Assessment Using Fishbone Diagram:

A Fishbone (Ishikawa) diagram was employed to evaluate potential risks and root causes affecting method performance. Parameters such as solvent type, wavelength, scanning speed, sampling intervals, and slit width were identified as significant risk factors (Figure 2).

 

 

Fig.2: Ishikawa Fishbone Diagram.

 

Optimization of the method through the Design of Experiment software:

The method was optimized using a CCD in Design‑Expert® Software V13 (Stat‑Ease Inc., USA), as summarized in Table 1. Optimization focused on scanning speed and solvent composition. A rutin concentration of 10µg/mL in methanol: deionized water (50:50, v/v)—representing the lower end of the validated linearity range—was selected for DoE trials to ensure robustness at minimal analyte levels. The CCD employed an alpha (α) value of 1, corresponding to a face‑cantered design with axial points at the same level as factorial points. Factor levels were defined as: Scanning speed: low (100nm/min), medium (200 nm/min), high (300nm/min), Solvent composition (methanol: water): low (25:75v/v), medium (50:50v/v), high (75:25v/v) Optimal conditions were determined based on maximum absorbance and desirability function. ANOVA confirmed the significance of the quadratic model (p<0.0001, F = 8676.41, adjusted R˛ ≈ 1.0). These findings validate the quadratic model as suitable for describing the relationship between scanning speed, solvent composition, and absorbance. Overall, the model was found to be highly significant.

 

Table 1. CCD Based experimental design matrix and optimization layout.

Run

 

Factor 1

A: Solvent Ratio%

Factor 2

B: Scanning Speed

Response 1 R1:

Absorbance (256nm)

1

50

0

0.424

2

75

-1

0.606

3

25

0

0.289

4

50

1

0.428

5

75

1

0.609

6

25

-1

0.289

7

25

1

0.290

8

75

0

0.611

9

50

0

0.424

 

Fig.3(A): 3d Response Surface Plot; 3(B): 2d Contour Plot of Absorbance Vs. Scanning Speed and Solvent Ratio; 3(C): Overlay Plot Obtained from Method Optimization Model; 3(D): Factor-Response Plot   

 

Fig.3(a):3D response surface plot was generated to visualize the combined effect of scanning speed and solvent ratio on absorbance. The surface exhibited a downward gradient from high absorbance at lower scanning speeds and solvent ratios to reduced absorbance at higher levels of both variables. This trend indicates a negative interaction between the two factors, suggesting that simultaneous increases in scanning speed and solvent ratio lead to a decline in absorbance. The color-coded surface and design points further support the model’s predictive capability and highlight the optimal region for maximum absorbance.

 

Fig.3(b): A two-dimensional contour plot was employed to illustrate the combined influence of scanning speed and solvent ratio on absorbance. The plot revealed a gradient from high absorbance (0.611) in the lower-left region to low absorbance (0.289) in the upper-right region, indicating that increasing both scanning speed and solvent ratio results in a decline in absorbance. The distribution of design points and contour transitions supports the presence of a negative interaction between the two variables, reinforcing the findings from the response surface analysis Fig.3(c):

 

An overlay plot was utilized to define the design space for the UV spectrophotometric method, mapping the interaction between scanning speed and solvent ratio. The yellow-shaded region represents the optimal zone where method criteria are simultaneously satisfied, indicating robust performance across the selected factor levels. The distribution of design points within this region confirms the feasibility and reliability of the chosen experimental conditions.

 

Fig.3(d): scatter plot was generated to evaluate the relationship between scanning speed and absorbance, with data points color-coded by experimental run. The correlation coefficient was found to be 0.010, indicating a negligible linear relationship between the two variables. Despite the variation in scanning speed, absorbance values remained relatively stable, suggesting that scanning speed alone does not significantly influence the absorbance response under the tested conditions

 

Analytical method validation:

Validation of the experimental design is a critical step in assessing both risk and reliability during method development, particularly within the QbD framework. This process ensures the appropriateness of the mathematical model in correlating key variables and achieving the desired outcomes within the established design space.

 

Specificity and selectivity:

The method exhibited no spectral interference at 256nm, confirming its specificity for rutin. This was further

substantiated by the solvent and analyte spectra presented in Figures 4 and 5.

 

Fig.4: Uv- Spectrum of Solvent Used For Method Validation

 

 

Fig.5: Uv- Spectrum of Rutin Showing λmax At 256nm

 

Linearity and range:

Figure 8. illustrates the calibration curve for Rutin, developed across the concentration range of 10–50μg/mL, with absorbance recorded at its maximum wavelength. The linearity curve for Rutin demonstrates a strong linear relationship between absorbance and concentration over the range of 10 to 50μg/mL. The regression equation obtained was y = 0.0268x – 0.015, with a correlation coefficient (R˛) of 0.9974, indicating excellent linearity and confirming the suitability of this range for quantitative analysis.

 

 

Fig.6: Calibration Curve Obtained for Rutin During Validation of Uv Spectrophotometric Method

 

Table 2. Linearity data for UV spectrophotometric method applied to Rutin

Sr. No

Concentration

Absorbance

1

10 µg/mL

0.237

2

20 µg/mL

0.556

3

30 µg/mL

0.774

4

40 µg/mL

1.046

5

50 µg/mL

1.332

 

LOD and LOQ:

LOD and LOQ were determined as per the ICH guidelines and were found to be 0.82 and 2.48μg/mL respectively.

 

Precision:

Precision was confirmed with %RSD. Values under 2% across six replicates at 10ug/mL. demonstrating the higher producibility in Table 4.

 

Robustness and Ruggedness

The method demonstrated ruggedness with respect to variation in the analyst, showing %RSD values below 2%. It also proved robust against slight changes in wavelength, with %RSD values remaining under 2%. The results of ruggedness and robustness are presented in Table 3.

 

Confirmation of Rutin Presence:

The presence of flavonoids in the extract obtained from the roots and leaves of Eucalyptus globulus was initially confirmed through a positive flavonoid identification test. Subsequent UV–visible spectral analysis revealed a distinct absorption maximum at 256nm (Figure.7a and b), which corresponds precisely to the λmax of rutin as established from the standard rutin spectrum. The concordance of these findings substantiates the presence of rutin in the extract and further validates the reliability of the analytical method employed.

 

Greenness Evaluation of the Developed Method:

Based on the greenness scoring scale (ranging from 0.00 to 1.00), values between 0.75 and 1.00 represent an excellent green method, scores from 0.50 to 0.74 are considered acceptable, while those below 0.50 indicate low environmental friendliness.

 

As shown in Fig.8 the developed analytical method achieved a greenness score of 0.60, classifying it as an acceptable green approach.

 

This outcome reflects the balance between strengths and limitations:

Strengths: Direct spectrophotometric detection without derivatization, minimal sample size, renewable solvents (ethanol and water), low energy consumption, and excellent operator safety.


 

 


Fig.7 (A) Absorption Curve for Leaves Extract

 

 

Figure 7 (B) Absorption Curve for Roots Extract


Table 3: Method Validation Report

Parameter

Condition

Conc. (µg/mL)

Observation 1

Observation 2

Mean

%RSD

Precision (Inter-day)

Day 1 and

Day 2

10

0.255

0.254

0.255

0.28

20

0.557

0.556

0.557

0.13

30

0.775

0.774

0.775

0.09

Precision (Intraday)

Same Day

10

0.254

0.253

0.254

0.28

20

0.557

0.555

0.556

0.25

30

0.774

0.773

0.774

0.09

Robustness (change in analyst)

Analyst 1

20

0.556

0.555

0.556

0.13

Analyst 2

20

0.555

0.554

0.555

0..13

Robustness (Wavelength)

254nm

20

0.527

0.526

0.527

0.13

256 nm

20

0.553

0.552

0.553

0.13

258 nm

20

0.552

0.550

0.551

0.26

 


Limitations:

Reliance on methanol as a hazardous solvent, ex situ preparation, limited automation, and low throughput due to manual handling.

 

 

Fig.8: Agree Circular Pictogram

 

CONCLUSIONS:

In the present study, rutin was successfully extracted from the roots and leaves of Eucalyptus globulus using a green extraction approach, namely ultrasound‑assisted extraction, which is both efficient and environmentally sustainable. Furthermore, a new, simple, accurate, and precise UV spectrophotometric method was developed and validated based on QbD principles for the detection of rutin in the plant extract. The integration of QbD ensured robustness, reproducibility, and reliability of the analytical procedure. This method not only provides an eco‑friendly alternative for rutin estimation but also serves as a practical tool for routine analysis of rutin in herbal formulations.

 

The developed method can be further extended for the standardization of herbal medicines and nutraceuticals containing rutin, as well as for quality control in pharmaceutical formulations. Its sustainability and simplicity make it a promising approach for broader applications in phytochemical profiling and regulatory compliance in herbal drug development. Additionally, The AGREE assessment yielded a high greenness score of 0.6, confirming that the developed method is strongly aligned with the principles of green analytical chemistry. This demonstrates its potential as an environmentally sustainable alternative for routine analytical applications.

 

ACKNOWLEDGMENTS

The author gratefully acknowledges the Principal Dr. Pramod Gadad and KLE College of Pharmacy, Nipani for providing the necessary facilities and support that enabled the successful completion of this research work.

 

CONFLICT OF INTEREST:

The authors declare no conflicts of interest.

 

SOURCES OF FUNDING:

No external funding was obtained for this research.

 

REFERENCES:

1.      Ganeshpurkar A, Saluja AK. The pharmacological potential of rutin. Saudi Pharm J. 2017; 25(2): 149-64. 2017  

2.      Abualhasan MN, Mansour J, Jaradat N, Zaid AN, Khadra I. Formulation and Development of a Validated UV‐Spectrophotometric Analytical Method of Rutin Tablet. International Scholarly Research Notices. 2017; 2017(1): 2624947

3.      Ishii K, Furuta T, Kasuya Y. Determination of rutin in human plasma by high-performance liquid chromatography utilizing solid-phase extraction and ultraviolet detection. J Chromatogr B Biomed Sci Appl. 2001; 759(1): 161-8.: Biomedical Sciences and Applications. 2001 Aug 5; 759(1): 161-8.

4.      Jafari F, Ramezani M, Nomani H, Amiri MS, Tafazoli Moghadam A, Sahebkar A, et al. Therapeutic effect, chemical composition, ethnobotanical profile of Eucalyptus globulus: a review. Lett Org Chem. 2021; 18(6): 419-52. doi:10.2174/1570178617999200807213043.

5.      Park JY, Kim JY, Son YG, Kang SD, Lee SW, Kim KD, et al. Characterization of chemical composition and antioxidant activity of Eucalyptus globulus leaves under different extraction conditions. Appl Sci (Basel). 2023; 13(17): 9984. doi:10.3390/app13179984.

6.      Guillon B, Muńiz-Mouro A, Lú-Chau TA, Moreira MT, Lema JM, Eibes G. Green approaches for the extraction of antioxidants from eucalyptus leaves. Ind Crops Prod. 2019; 138: 111473. doi: 10.1016/j.indcrop.2019.111473.

7.      Lima L, Pereira AI, Vaz CB, Ferreira O, Dias MI, Heleno SA, et al. Optimization of heat and ultrasound-assisted extraction of Eucalyptus globulus leaves reveals strong antioxidant and antimicrobial properties. Food Chemistry. 2025; 479: 143755. doi: 10.1016/j.foodchem.2025.143755

8.      Fukuda IM, Pinto CF, Moreira CD, Saviano AM, Lourenço FR. Design of experiments (DoE) applied to pharmaceutical and analytical quality by design (QbD). Braz J Pharm Sci. 2018; 54: e01006. 2018 Nov 8; 54: e01006.

9.      Bairagi A, Kothrukar R, Chikhale H, Kosanam S, Borse L. AQbD-novel strategy for analytical methods. Future J Pharm Sci. 2024;10(1): 138. 2024 Oct 4; 10(1): 138.

10.   Thorsteinsdóttir UA, Thorsteinsdóttir M. Design of experiments for development and optimization of a liquid chromatography coupled to tandem mass spectrometry bioanalytical assay. J Mass Spectrom. 2021; 56(9): e4727.

11.   Szpisják-Gulyás N, Al-Tayawi AN, Horváth ZH, László Z, Kertész S, Hodúr C. Methods for experimental design, central composite design and the Box–Behnken design, to optimise operational parameters: A review. Acta Aliment. 2023; 52(4): 521-37.

12.   Rao TN. Validation of analytical methods. In: [Editor(s)]. Calibration and validation of analytical methods: a sampling of current approaches. Cham: Springer; 2018. p. 131-41.

13.   Yuwono M, Indrayanto G. Validation of chromatographic methods of analysis. Profiles Drug Subst Excip Relat Methodol. 2005; 32: 243-59.

 

 

 

 

 

Received on 04.05.2026      Revised on 02.06.2026

Accepted on 29.06.2026      Published on 12.10.2026

Available online from October 21, 2026

Asian Journal of Pharmaceutical Analysis. 2026; 16(4):251-258.

DOI: 10.52711/2231-5675.2026.00039

©Asian Pharma Press All Right Reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.